ADJUSTMENT
1.
Disconnect wire assembly (12) from solenoid.
2.
Position starter assembly in soft-jawed vise and connect to 24V battery using three jumper wires. Do not connect ground
to MTR terminal at this time.
3.
Momentarily flash jumper lead A from ground to MTR terminal. The drive (60) will shift into cranking position.
4.
Press on drive (60) to take up movement.
5.
Using thickness gage, measure pinion clearance.
6.
Adjust pinion by turning locknut (3) until pinion clearance is 0.36 in.
7.
Remove three jumper wires.
8.
Install new preformed packing (4) and plug (5).
9.
Connect wire assembly (12) to solenoid ground.
5
4
3 (HIDDEN)
3
60
12
394-1755
394-1383
10.
Install starting motor (WP 0057 00).
11.
Start engine and verify correct operation of starting system (TM 5-380-248-10).
END OF WORK PACKAGE