TM 5-3805-248-23-2
STARTING MOTOR (DELCO-REMY) REPAIR - CONTINUED
0361 00
ASSEMBLY - CONTINUED
46. Install three screws (28).
47. Install bushing (27), insulator (26), washer (25), lockwasher (24) and nut (23).
NOTE
Two brush terminal wires connected to field coil must be in alignment with plug ports in housing before pro-
ceeding to assemble.
48.
Position plate (20) assembly, aligning match-marks on end frame (29) with match-marks on housing (13).
49.
Install plate (20) assembly by pulling armature (47) out just far enough to compress brushes to install on commutator.
50.
Install four bolts (30).
47
28
27
26
25
24
23
20
29
30
394-1375
51.
Install two screws (18) securing field coil (19).
52.
Install two new seals (14) and plugs (15).
53.
Connect wire assembly (12).
54.
Install washer (21) and nut (22).
55.
Install connector (16) and nut (17). Torque nut (17) to 22 lb-ft (30 Nm).
17
16
15
14
13
12
18
19 (HIDDEN)
21
20 (HIDDEN)
22
14
15
394-1374
0361 00-13