TM 5-3805-260-24
CRANKCASE VENTILATOR VALVE
DISASSEMBLE CRANKCASE VENTILATOR
VALVE
NOTE: The crankcase ventilator valve can be
disassembled while installed on the engine. The
valve was removed for better photo illustration.
1.
Remove screws (2) that hold cover (3) on
housing (1).
2.
Remove cover (3) and spring (4) from the
housing.
3.
Remove the piston, sleeve (8), retainer (9), and
diaphragm (7) from the housing as a unit.
4.
Remove inner sleeve (6) and gasket (5) from
the housing.
5.
Remove nut ( 12), washer (13), spacer ( I ),
piston (10), diaphragm (7), and the retainer from
sleeve (8).
3-33