TM 5-3805-260-24
AIR CLEANER HOUSING AND PANEL ASSEMBLY
INSTALL AIR CLEANER HOUSING
AND PANEL ASSEMBLY
1.
Put the air cleaner housing and panel assembly
(1) in position on the machine.
2.
Put handle assembly (2) in position and install
the five bolts (3), the washers and one nut to
hold the handle assembly.
3.
Install bolt (4), the washer and nut to hold the
top of the panel assembly to the hydraulic tank.
4.
Install the four washers and nuts (6) to hold the
bottom of the panel assembly in position.
5.
Connect air indicator hose (5) to the air cleaner
housing and tighten the clamp to a torque of 18
+ 5 lb. ft. (24 + 7 N-m).
6.
Connect the hose for the engine air intake and
tighten clamp (7) to a torque of 18 + 5 lb. ft. (24
+ 7 N m).