TM 5-3805-260-24AIR CLEANER HOUSING AND PANEL ASSEMBLYINSTALL AIR CLEANER HOUSINGAND PANEL ASSEMBLY1.Put the air cleaner housing and panel assembly (1) in position on the machine.2.Put handle assembly (2) in position and install the five bolts (3), the washers and one nut to hold the handle assembly.3.Install bolt (4), the washer and nut to hold the top of the panel assembly to the hydraulic tank.4.Install the four washers and nuts (6) to hold the bottom of the panel assembly in position.5.Connect air indicator hose (5) to the air cleaner housing and tighten the clamp to a torque of 18 + 5 lb. ft. (24 + 7 N-m).6.Connect the hose for the engine air intake and tighten clamp (7) to a torque of 18 + 5 lb. ft. (24 +7 N m).3-38