TM 5-3805-260-24ELEVATOR RELIEF VALVEREMOVE ELEVATOR RELIEFVALVEWARNING: All pressure must be releasedfrom the hydraulic system before any lines aredisconnected.1. Remove relief valve (2) from the bottom of hous-ing (1). The housing is mounted on the hydraulicpump.VIEW FROM UNDER MACHINE2. Remove O-ring seal (3) and gasket (5) from therelief valve. Remove nut (4) and the screw.Check the condition of the seal. If the seal hasdamage, use new parts for replacement.3. Remove O-ring seal (6) from screw (7). Checkthe condition of the seal. If the seal has damage,use new parts for replacement.4. Remove spring (9), plunger, seat and valve fromthe shell (8).5. Remove O-ring seal (10) and ring (12) fromplunger (I I). Check the condition of the seal. Ifthe seal has damage, use new parts for replace-ment.4-108