• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
TRACK AND BLADE CONTROL BOX REPAIR - Continued
Figure 1. Track and Blade Control Box Removal. - Continued

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  95    96    97    98    99  100  101    102    103    104    105  
img
. . .
TM 5-2350-377-13&P
0029
FIELD MAINTENANCE
TRACK AND BLADE CONTROL BOX REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic's: Automotive
Battery box open (TM 5-2350-262-20)
Negative battery cables disconnected
(WP 0071, Table 1, Item 7)
(TM 5-2350-262-20)
Personnel Required
Construction Equipment Repairer, 91L
REMOVAL
1.
Remove control box power harness connector (Figure 1, Item 1) from track and blade control box
(Figure 1, Item 2).
2.
Remove manifold harness connector (Figure 1, Item 3) from track and blade control box (Figure 1, Item 2).
3.
Remove two screws (Figure 1, Item 6) and two washers (Figure 1, Item 5) from instrument panel
(Figure 1, Item 4).
4.
Slide track and blade control box (Figure 1, Item 2) upward from behind instrument panel (Figure 1, Item 4).
2
3
1
4
5
5
6
6
M0001HBF
Figure 1. Track and Blade Control Box Removal.
END OF TASK
0029-1
03/15/2011Rel(1.8)root(maintwp)wpno(M00002)