TRACK AND BLADE CONTROL BOX REPAIR
Figure 3. Control Box Assembly.

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  92    93    94    95    96  97  98    99    100    101    102  
img
. .
TM 5-2350-377-13&P
0028
DISASSEMBLY - Continued
4.
Remove four screws (Figure 2, Item 1) and cover (Figure 2, Item 3) from control box (Figure 2, Item 7).
5.
Refer to Control Box Power Wiring Harness Replacement (WP 0025) to remove control box wiring harnesses
(Figure 2, Items 6 and 8) inside control box (Figure 2, Item 7).
6.
Remove four jam nuts (Figure 2, Item 4), washers (Figure 2, Item 5), and switches (Figure 2, Item 2) from cover
(Figure 2, Item 3).
1
2
3
4, 5
3
6
7
8
M0108HBF
Figure 2.
Control Box Disassembly.
END OF TASK
0028-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00023)