TM 5-2350-377-13&P
0039
REMOVAL - Continued
b.
Remove flow valve (Figure 2, Item 3) from each valve body (Figure 2, Item 4).
CAUTION
Be ready to secure valves located under brackets when removing fastening hardware. Failure
to do so may cause damage to equipment.
2.
Holding valve removal:
a.
Remove two screws (Figure 2, Item 1), four flat washers (Figure 2, Item 2), two lockwashers
(Figure 2, Item 7), nuts (Figure 2, Item 8), and valve bodies (Figure 2, Item 5) from bracket
b.
Remove valve (Figure 2, Item 10) and check valve (Figure 2, Item 9) from each holding valve body
(Figure 2, Item 5).
1
1
10
2
2
9
3
4
10
5
4
9
6
5
2
7
7
8
8
M0054HBF
Figure 2. Flow Valves Removal.
END OF TASK