TM 5-2350-377-13&P
0049
TYPICAL PANEL MOUNTING RECEPTACLE
DISASSEMBLY
1.
Remove nut from shell assembly and slide back on cable (Figure 1).
2.
Push grommet back on cable (Figure 1).
3.
Push contacts out through rear of insert with pin extractor (Figure 1).
4.
Push insert out through rear of shell (Figure 1).
5.
Unsolder cable leads from contacts (Figure 1).
6.
Remove grommet and nut from cable (Figure 1).
ASSEMBLY
1.
Slide nut over cable (Figure 1).
2.
Slide grommet over cable leads (Figure 1).
3.
Strip cable insulation equal to depth of solder wells of contacts (Figure 1).
4.
Insert cable into solder wells of contacts and solder (Figure 1).
5.
Push insert into shell from rear until seated. Groove in insert must be aligned with guide in shell to ensure
proper fit (Figure 1).
6.
Push contacts into insert from rear until seated (Figure 1).
7.
Push grommet down cable and over solder wells of contacts (Figure 1).
8.
Install nut on shell assembly (Figure 1).
CABLE
GROMMET
GROOVE
SHELL
CONTACTS
INSERT
NUT
(PIN OR SOCKET)
M0117HBF
Figure 1.
Panel Mount Receptacle Repair.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00032)