TM 5-3800-205-23-1
HYDRAULIC SYSTEM OIL SAMPLING VALVE REPLACEMENT - CONTINUED
0117 00
REPLACEMENT - CONTINUED
2.
Remove oil sampling valve (1) and O-ring (2) from tube fitting (3). Discard O-ring.
3.
Lightly coat new O-ring (2) with clean oil.
4.
Install new O-ring (2) and oil sampling valve (1) to tube fitting (3).
1,2
390-1018
3
5.
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside. Failure to
follow this warning may cause injury or death due to carbon monoxide poisoning.
6.
Start engine (TM 5-3800-205-10-1 or TM 5-3800-205-10-2). Move hydraulic control levers through all positions.
Check for leaks.
END OF WORK PACKAGE
0117 00-2