TM 5-3800-205-23-1
HYDRAULIC TANK SIGHT GAGE REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Equipment Condition
Machine parked on hard, level surface (TM 5-3800-
Unit
205-10-1 or TM 5-3800-205-10-2)
Tools and Special Tools
Scraper bowl or water tank lowered to ground (TM
Tool kit, general mechanic's (Item 33, WP 0172
5-3800-205-10-1 or TM 5-3800-205-10-2)
Parking brake applied (TM 5-3800-205-10-1 or TM
Materials/Parts
5-3800-205-10-2)
Wheels chocked (TM 5-3800-205-10-1 or TM 5-
3800-205-10-2)
Grommet
Battery disconnect switch in OFF position (TM 5-
O-ring (4)
3800-205-10-1 or TM 5-3800-205-10-2)
References
Hydraulic tank drained below level of sight gage
REMOVAL
CAUTION
While reaching inside hydraulic tank, hold sight glass assembly to prevent sight glass from falling to bottom
of tank as screws are removed. Failure to follow this caution may result in damage to sight glass.
1.
Remove four screws (1) and plate (2) from hydraulic oil tank (3).
1,2
3
390-1801