TM 5-3800-205-23-1
HYDRAULIC TANK SAFETY RELIEF VALVE ASSEMBLY MAINTENANCE - CONTINUED
0118 00
CLEANING AND INSPECTION
1.
Clean dust and dirt from relief valve filter with detergent, water, and rags. Dry with clean rags.
2.
Inspect relief valve filter for damage and dirt that cannot be removed. Replace filter if damaged or if dirt cannot be
cleaned.
CAUTION
Clean outside surfaces of relief valve only. DO NOT permit detergent, water or dirt to enter inside relief
valve.
3.
Clean outside of relief valve with detergent, water, and rags. Dry with clean rags.
4.
Inspect relief valve for damage. Replace relief valve if damaged.
ASSEMBLY
NOTE
Inside of filter is tapered and can only be installed in one direction.
1.
Coat with oil and install two new O-rings (7) on relief valve (1). Install filter (6).
2.
Install cover (5) on relief valve (1) with new retaining ring (4).
INSTALLATION
1.
Coat with oil and position new O-ring (3) on relief valve (1).
2.
Install relief valve (1) assembly on top of hydraulic
tank (2).
1
2
END OF WORK PACKAGE
0118 00-3