TM 5-3800-205-23-1
FUEL UNIT INJECTOR REPLACEMENT - CONTINUED
0139 00
INSTALLATION - CONTINUED
6.
Install forcing bridge (11) with three bolts (12) and
11
12,13
hard washers (13). Place two long legs of forcing
bridge in two vacated rocker arm shaft support holes
closest to injector. Short leg of forcing bridge sits on
intake manifold bolt boss.
CAUTION
Damage to head could occur if bridge mounting bolts are not tightened to specified torque.
7.
Tighten forcing bridge mounting bolts (12) to 21 lb-ft (28 Nm).
CAUTION
Ensure that forcing bolt turns freely and has no damaged threads.
Complete lubrication of forcing bolt threads must be maintained for each injector seating procedure.
Failure to relubricate before setting next injector may cause premature wear or tool damage.
0139 00-4