TM 5-3805-248-23-1
BATTERY, STARTING AND CHARGING SYSTEM TROUBLESHOOTING
PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Starting Motor
3.
Test voltage to start switch.
Inoperative - Continued.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
b. Set multimeter to appropriate
orange wire on start switch and
ground.
0010 00-7