TM 5-3805-248-23-1
ELECTRICAL ACCESSORIES TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Low Air Pressure Warning
Light Always on (Air
Pressure OK).
WARNING
Remove all jewelry, watch, rings, etc. prior to disconnecting cables from batter-
ies or other electrical source. Items can come in contact with battery or electrical
source and cause electrical shock. Failure to follow this warning may cause
injury or death.
Make sure wheels are chocked and bowl is lowered to ground for all tests. Fail-
ure to do so may cause injury or death.
Eye protection must be worn when performing maintenance where components
or particles could fly out during procedure. Failure to take precautions may
cause injury.
NOTE
1.
Disconnect low air pressure warning
1. If light goes out, replace low air pressure
2. If light stays on, repair short to ground
between low air pressure warning lamp
switch and low air pressure warning
lamp.