TM 5-3805-248-23-1
ELECTRICAL ACCESSORIES TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
If battery voltage is present, go to Test
2.
Engine Cranks but Fails to
d. Place battery disconnect switch in
6.
Start in Cold Weather
ON position (TM 5-3805-248-10).
2.
If no voltage is present, repair open
(Ether Starting Aid
circuit between fuse number 2 and
Inoperative) - Continued.
ether start switch.
6.
Test ether start switch.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
c. Disconnect ether start switch
d. Connect multimeter positive lead to
terminal that purple wire was
removed from (switch side) and
that orange wire was removed from
(switch side).
394-1628