TM 5-3805-248-23-1
ELECTRICAL ACCESSORIES TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Engine Cranks but Fails to
ether start switch.
circuit between ether start switch and
Start in Cold Weather
(Ether Starting Aid
Inoperative) - Continued.
3. If problem still exists, go to Engine
Troubleshooting (WP 0009 00).
3.
Air Dryer Heater Is
Inoperative.
WARNING
Remove all jewelry, watch, rings, etc. prior to disconnecting cables from batter-
ies or other electrical source. Items can come in contact with battery or electrical
source and cause electrical shock. Failure to follow this warning may cause
injury or death.
Make sure wheels are chocked and bowl is lowered to ground for all tests. Fail-
ure to do so may cause injury or death.
Eye protection must be worn when performing maintenance where components
or particles could fly out during procedure. Failure to take precautions may
cause injury.
NOTE
1.
Inspect fuse #6 on reverse side of
instrument panel.
2. If fuse blows again, check for short to
ground between fuse box and air dryer
3. If wiring is OK, replace air dryer (WP
4. If fuse is OK, go to Test 2.