TM 5-3805-248-23-1
COOLANT FILTER MOUNTING, HOSES AND FITTINGS REPLACEMENT - CONTINUED
0051 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Clean all parts with solvent.
2.
Dry all parts with compressed air.
3.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Install elbow (19).
2.
Install tee (18) on elbow (19).
3.
Install adapter (17) on tee (18).
4.
Install hose (3) on adapter (17).
5.
Install tee (20).
6.
Install bushing (21) on tee (20).
7.
Install elbow (22) on bushing (21).
0051 00-4