TM 5-3805-248-23-1
TRANSMISSION OIL SAMPLING VALVE REPLACEMENT - CONTINUED
0127 00
INSTALLATION
1.
Remove 9/16-18-2A THD plug.
NOTE
Lubricate all preformed packings with clean lubricating oil prior to installation.
2.
Install new preformed packing (1), adapter (2), new preformed packing (3) and transmission oil sampling valve (4).
3.
Install cap (5) on valve (4).
4.
Read sight gage to determine fluid level (TM 5-3805-248-10).
5.
Add transmission fluid to maintain level between ADD and FULL marks (TM 5-3805-248-10).
END OF WORK PACKAGE
0127 00-3/(-4 blank)