TM 5-3805-248-23-2
EJECTOR ASSEMBLY REPLACEMENT - CONTINUED
0328 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Clean all parts with solvent cleaning compound.
2.
Dry all parts with compressed air.
3.
Inspect all parts for damage and replace as necessary.
INSTALLATION
WARNING
Make sure chains are placed on the ejector assembly to equally carry the weight of the ejector assembly.
Failure to follow this procedure can cause injury or equipment damage.
1.
Install three chains on ejector assembly.
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
NOTE
Weight of ejector assembly is 1,300 lb (590 kg).
2.
Using lifting device, position ejector assembly in vehicle.
3.
4.
5.
6.
Remove lifting device.
7.
8.
Operate ejector and verify correct operation (TM 5-3805-248-10).
END OF WORK PACKAGE
0328 00-3/-4 Blank