TM 5-3805-260-24
20. Secure three stator leads to regulator (18)
with nuts (19).
21. Attach regulator cover (17) to stator housing
with four screws (16).
22. Install washer (15) and plate (14).
23. Install bearing (13) in end frame (6).
24. Install collar (10), retainer (9), and three
screws (8).
25. Install rotor (7) shaft into end frame (6).
26. Secure end frame assembly to stator
housing with four bolts (5).
27. Install fan (4), pulley (1), locknut (2), and
washer (3).
28.
Position alternator in a vise or
similar clamping device.
CAUTION
Be careful not to overtighten alternator
in vise. Damage is possible to
alternator if vise is overtightened. 29.
Tighten locknut (2) to a torque of 70 to
80 lb. ft. (95 to 109 N. m).
30. The rotor normally retains magnetism to
provide voltage buildup as the rotor turns.
However, after disassembly it may be
necessary to remagnetize the rotor. Use
the following procedures to magnetize the
rotor:
( 1) Install the alternator.
(2) Remove protective cap (38) from alter- nator
relay terminal.
(3)
Momentarily connect a jumper lead from
the battery positive post to the relay
terminal on the alternator.
(4)
Install protective cap (38) on alternator relay
terminal.
3-11