TM 5-3805-260-2420. Secure three stator leads to regulator (18)with nuts (19).21. Attach regulator cover (17) to stator housingwith four screws (16).22. Install washer (15) and plate (14).23. Install bearing (13) in end frame (6).24. Install collar (10), retainer (9), and threescrews (8).25. Install rotor (7) shaft into end frame (6).26. Secure end frame assembly to statorhousing with four bolts (5).27. Install fan (4), pulley (1), locknut (2), andwasher (3).28. Position alternator in a vise orsimilar clamping device.CAUTIONBe careful not to overtighten alternatorin vise. Damage is possible toalternator if vise is overtightened. 29.Tighten locknut (2) to a torque of 70 to80 lb. ft. (95 to 109 N. m).30. The rotor normally retains magnetism toprovide voltage buildup as the rotor turns.However, after disassembly it may benecessary to remagnetize the rotor. Usethe following procedures to magnetize therotor:( 1) Install the alternator.(2) Remove protective cap (38) from alter- natorrelay terminal.(3)Momentarily connect a jumper lead fromthe battery positive post to the relayterminal on the alternator.(4)Install protective cap (38) on alternator relayterminal.3-11
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business