CONTROL BOX POWER WIRING HARNESS REPLACEMENT - Continued
CONTROL BOX POWER WIRING HARNESS REPLACEMENT - Continued

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  83    84    85    86    87  88  89    90    91    92    93  
img
.
TM 5-2350-377-13&P
0025
INSTALLATION
1.
Install control box power harness connector (Figure 5, Item 1) on track and blade control box
(Figure 5, Item 2).
1
2
M0097HBF
Figure 5. Control Box Power Wiring Harness Installation.
2.
Remove four screws (Figure 6, Item 2) from ejector panel (Figure 6, Item 1) and move panel downward,
retaining screws for future use.
1
2
M0098HBF
Figure 6. Control Box Power Wiring Harness Installation.
0025-4
03/15/2011Rel(1.8)root(maintwp)wpno(M00020)