• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Blade Folder Wiring Harness Removal.
CONTROL BOX POWER WIRING HARNESS REPLACEMENT

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  79    80    81    82    83  84  85    86    87    88    89  
img
.
TM 5-2350-377-13&P
0024
INSTALLATION
1.
Connect hull wiring harness leads (Figure 2, Item 5) to blade folder harness (Figure 2, Item 6), matching lead
numbers.
2.
Route blade folder harness through opening on lower left side into operator's compartment behind ejector
panel.
3.
Route control box power harness (Figure 2, Item 7) behind ejector panel.
4.
Connect blade folder harness lead #514 (Figure 2, Item 4) to control box power harness (Figure 2, Item 3).
5.
Connect bilge pump light lead #450 (Figure 2, Item 2) to blade folder harness lead #515 (Figure 2, Item 1).
2
3
1
7
6
5
4
M0092HBF
Figure 2. Blade Folder Wiring Harness Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
Unblock front of vehicle (TM 5-2350-262-20).
END OF TASK
END OF WORK PACKAGE
0024-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00019)