Figure 1. Headlight Wiring Harness Removal.
Figure 1. Blade Folder Wiring Harness Removal.

Maintenance Manual For The Hydraulic Blade Folder-Track Tensioner For Armored Combat Earthmover, M9
Page Navigation
  77    78    79    80    81  82  83    84    85    86    87  
img
. .
TM 5-2350-377-13&P
0023
INSTALLATION
1.
Route headlight wiring harness (Figure 2, Item 2) through openings in top of four braces (Figure 2, Item 10)
inside apron (Figure 2, Item 4) back wall, starting from left headlight to right headlight.
2.
Install nut (Figure 2, Item 6), new lockwasher (Figure 2, Item 5), flat washer (Figure 2, Item 7), and hose clamp
(Figure 2, Item 8) to headlight wiring harness and apron stud (Figure 2, Item 9).
3.
Connect two apron wiring harness (Figure 2, Item 2) terminals to two apron mercury switch terminals
(Figure 2, Item 1).
4.
Connect headlight wiring harness (Figure 2, Item 2) to apron wiring harness (Figure 2, Item 3) at terminals.
4
3
2
1
6
5
7
10
8
9
M0090HBF
Figure 2.
Headlight Wiring Harness Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
Install LH and RH headlight assembly (WP 0030).
END OF TASK
END OF WORK PACKAGE