TM 5-3800-205-10-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0012 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
SCRAPER SYSTEM - CONTINUED
1. Clean any debris from floor
6.
Floor Opens During Operation.
1. Check floor area for any
area. If problem still exists, go
buildup of debris that would
to test step 2.
stop floor from closing. If floor
is not closing properly, it may
cause
floor
to
open
prematurely.
2. Check that control levers are in
2. Place control levers in hold
hold position.
position if required. If problem
still exists, go to test step 3.
3. Clean any debris from lever. If
3. Check control lever for
any damage is found, notify
damage or debris that would
Unit Maintenance.
restrict freedom of movement,
and/or automatic return to hold
position.
7.
Travel Time of Bowl Lift Cylinders is
1. Check bowl hydraulic lift
1. Clean any debris from
cylinder(s). If problem still
Slow.
cylinders for any buildup of
debris.
exists, go to test step 2.
2. Check hydraulic oil level.
2. If hydraulic oil level is low, fill
If problem still exists, go to test
step 3.
3. Clean any debris from lever. If
3. Check control lever for
any damage is found, notify
damage or debris that would
Unit Maintenance.
restrict freedom of movement,
and/or automatic return to hold
position.
8.
Travel Time of Ejector (Floor) is Slow.
1. Check ejector area for any
1. Clean any debris from ejector
buildup of debris.
area. If problem still exists, go
to test step 2.
2. Check hydraulic oil level.
2. If hydraulic oil level is low, fill
If problem still exists, go to test
step 3.
3. Clean any debris from lever. If
3. Check control lever for
any damage is found, notify
damage or debris that would
Unit Maintenance.
restrict freedom of movement,
and/or automatic return to hold
position.