TM 5-3805-248-23-1
ELECTRICAL ACCESSORIES TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
Check for voltage to backup alarm.
10. Back-up Alarm Is
Inoperative - Continued.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
b. Set multimeter to appropriate
black wire on backup alarm (harness
side) and multimeter negative lead
to chassis ground.
394-1569
d. Place battery disconnect switch in
1. If battery voltage is not indicated, repair
ON position (TM 5-3805-248-10).
open circuit between backup alarm and
2. If battery voltage is indicated, go to Test
7.
7.
Check backup alarm ground circuit.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
black and pink wire on backup alarm
and multimeter negative lead to
chassis ground.
0011 00-27