TM 5-3805-248-23-1
BOWL INTERMEDIATE HOSES, LINES AND FITTINGS REPLACEMENT - CONTINUED
0240 00
REMOVAL - CONTINUED
NOTE
Use a container to capture draining hydraulic oil. Dispose of hydraulic oil IAW local policy and ordi-
nances. Ensure all spills are cleaned up.
Tag hose and tube assemblies prior to removal to ensure correct installation.
Note routing of all hose assemblies prior to removal to ensure correct installation.
Remove and note location of all clips that secure hose assemblies to ensure correct installation.
1.
Remove bowl intermediate hydraulic hose assembly
2,3
1
4,5
6,7
8,9 (HIDDEN)
2.
Remove four capscrews (6), washers (7) and two
flange halves (8) from behind ejector.
3.
Disconnect hose assembly (10) from tube assembly
(1).
4.
Remove preformed packing (9) from hose assembly
(10) and discard.
5.
Remove two bolts (2), sleeves (3), spacer (4) and
flange half (5) from tube assembly (1).
6.
Remove tube assembly (1).
394-558
10
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Remove all preformed packing material from mounting surfaces.
2.
Clean all metal parts with solvent and rubber parts with detergent.
0240 00-2