TM 5-3805-248-23-1
EJECTOR CYLINDER REPLACEMENT - CONTINUED
0243 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Clean all parts with solvent.
2.
Dry all parts with compressed air.
3.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Position wood blocks on ejector cross member.
2.
Attach lifting device to fixed end and lower ejector cylinder assembly (5) through hull opening.
3.
Position ejector cylinder assembly (5) on wood blocks.
4.
Attach lifting device to both ends of ejector cylinder assembly (5).
5.
Use suitable lifting device to align fixed end of ejector cylinder with mounting bracket.
6.
Install pin (3), two washers (2), locks (4) and four bolts (1).
2,3
1
4
5
394-563
7.
Attach lifting device to ejector frame.
8.
Use lifting device to align ejector cylinder assembly (5) with ejector frame.
0243 00-4