TM 5-3805-248-23-2
GOVERNOR ASSEMBLY REPAIR - CONTINUED
0354 00
ASSEMBLY - CONTINUED
CAUTION
Exercise care when assembling parts in the following step. Refer to illustration to make sure all parts are in
the correct position. Failure to follow this procedure could result in damage to the governor assembly.
10.
Assemble insulator (72), full load stop bar (71),
64
shim(s) (70), retainer (69), contact (68), insulator (67)
65
then retainer spring (66) and install in governor
66
assembly housing (8).
67
68
11.
Install locking plate (65) and two bolts (64). Lock tabs
69
must face outward.
70
71
72
8
394-1223
12.
Install stop plunger (62) and spring (63) in governor
8
assembly housing (8).
13.
Install spring pin (61).
14.
Install core plug (60) in governor assembly housing
(8).
63
62
61 60
394-1222
15.
Install new preformed packing (59) and sleeve (58) in
cylinder (38).
38
16.
Install piston and valve assembly (57) in cylinder (38).
57
58
59
394-1221
0354 00-7