TM 5-3805-248-23-2
GOVERNOR ASSEMBLY REPAIR - CONTINUED
0354 00
FUEL SETTING PROCEDURE - CONTINUED
Example 4
Actual Reading:
-2.77 mm
Desired Setting:
-1.85 mm
Difference:
0.92 mm
The desired setting is higher than actual reading. Turn adjusting screw out (counterclockwise) approximately 1-1/8
turns. Recheck new setting and readjust if necessary.
Example 5
Actual Reading:
+1.05 mm
Desired Setting:
-1.25 mm
Difference:
2.30 mm
The desired setting is lower than actual reading. Turn adjusting screw in approximately 2-7/8 turns.
Example 6
Actual Reading:
-1.05 mm
Desired Setting:
+1.25 mm
Difference:
2.30 mm
The desired setting is higher than actual reading. Turn adjusting screw out approximately 2-7/8 turns.
0354 00-19