TM 5-3805-248-23-2
GOVERNOR ASSEMBLY REPAIR - CONTINUED
0354 00
FUEL SETTING PROCEDURE - CONTINUED
Example 1
Actual Reading:
1.05 mm
Desired Setting:
1.25 mm
Difference:
0.20 mm
Since desired setting is higher than actual reading, turn adjusting screw out (counterclockwise) approximately 1/4 turn.
Recheck new setting and readjust if necessary.
Example 2
Actual Reading:
2.77 mm
Desired Setting:
1.85 mm
Difference:
0.92 mm
Since desired setting is lower than actual reading, turn adjusting screw in (counterclockwise) approximately 1-1/8 turns.
Recheck new setting and readjust if necessary.
Example 3
Actual Reading:
-1.05 mm
Desired Setting:
-1.25 mm
Difference:
0.20 mm
Negative numbers work differently than positive numbers. If one number (-1.25) has a larger digital value than another
one (-1.05), first number (-1.25) is actually less than other one. Therefore, in this example desired setting is lower than
actual reading. Turn adjusting screw in (clockwise) approximately 1/4 turn. Recheck new setting and readjust if neces-
sary.
0354 00-18