TM 5-3805-248-23-2
GOVERNOR ASSEMBLY REPAIR - CONTINUED
0354 00
FUEL SETTING PROCEDURE - CONTINUED
GOVERNOR HOUSING
RACK STOP COLLAR
(HIDDEN)
101
394-1715
16.
Remove adjustment screw cover (101) from rear of governor housing.
NOTE
The static fuel setting (step 17) and the static full torque setting (step 18) must be within +0.00984 in. (.25
mm) of the setting on the engine information plate. If the setting is within +0.00984 in. (.25 mm), an adjust-
ment is not necessary.
17.
Slowly turn rod (97) out (counterclockwise) until circuit tester light comes on. This is static fuel setting.
18.
Continue to turn rod (97) out until indicator hands stops moving. Then turn rod out two additional turns. Push in on rack
stop collar to ensure it is in correct position. New reading on indicator is full torque static setting.
Example:
Static Fuel Setting = 0.0858 in. (2.18 mm)
Full Torque = 0.1252 in. (3.18 mm)
This means the torque rise setting is 0.0393 in. (1.00 mm). A fuel setting and torque rise setting are not necessary.
19.
Refer to engine information plate for correct static full torque setting.
20.
Determine how much the settings will have to be changed. (See examples in this work package.) Use Table 1 in this
work package to determine how far adjusting screws must be turned.
0354 00-16