INSTALLATION - Continued
2.
Secure two blade folder hoses (Figure 7, Item 2) with two clamps (Figure 7, Item 3), one flat washer
(Figure 7, Item 4), new lockwasher (Figure 7, Item 5), and screw (Figure 7, Item 6) to hole on hull plate
(Figure 7, Item 1) next to right side fire extinguisher.
1
2
3
4
5
3
6
M0070HBF
Figure 7. Blade Folder Hose Clamps Installation.
3.
Secure two blade folder hoses (Figure 8, Item 2) with two clamps (Figure 8, Item 3), one flat washer
(Figure 8, Item 4), new lockwasher (Figure 8, Item 5), and screw (Figure 8, Item 6) to hole on hull member
(Figure 8, Item 1).
2
1
3
2
4
5
6
3
M0071HBF
Figure 8. Blade Folder Hose Clamps Installation.