TM 5-3800-205-23-1
ENGINE OIL SAMPLING VALVE REPLACEMENT
THIS WORK PACKAGE COVERS
Removal
INITIAL SETUP
Equipment Condition
Maintenance Level
Machine parked on hard, level surface (TM 5-3800-
Unit
205-10-1 or TM 5-3800-205-10-2)
Tools and Special Tools
Scraper bowl or water tank lowered to ground (TM
5-3800-205-10-1 or TM 5-3800-205-10-2)
Tool kit, general mechanic's (Item 33, WP 0172
Parking brake applied (TM 5-3800-205-10-1 or TM
5-3800-205-10-2)
Materials/Parts
Wheel chocked (TM 5-3800-205-10-1 or TM 5-
3800-205-10-2)
Battery disconnect switch in OFF position (TM 5-
O-ring
3800-205-10-1 or TM 5-3800-205-10-2)
REPLACEMENT
1.
Remove oil sampling valve (2) and O-ring (3) from fitting (1). Discard O-ring.
2.
Lightly coat new O-ring (3) with clean oil.
3.
Install new O-ring (3) and oil sampling valve (2) to fitting (1).
.
1
2,3
390-991