TM 5-3800-205-23-2
FLOOR CHECK VALVE REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts - Continued
Maintenance Level
Direct Support
O-ring (as required)
Tools and Special Tools
References
TM 5-3800-205-23-1
Materials/Parts
Equipment Condition
Toolbox and rear deck cover removed (WP 0017
Quick disconnects at right side of draft arms dis-
connected (TM 5-3800-205-10-1)
WARNING
Do NOT disconnect or remove any hydraulic system line or fitting unless engine is shut down
and hydraulic system pressure has been relieved. Tighten all connections before applying pres-
sure. Escaping hydraulic fluid under pressure can penetrate the skin, causing serious injury.
At operating temperature hydraulic is hot. Allow hydraulic oil to cool before disconnecting
any hydraulics. Failure to do so could result in injury.
Hydraulic oil is very slippery. Immediately wipe up any spills. Failure to follow this warning
may result in injury to personnel.
CAUTION
Cap all hoses to prevent fluid loss and contamination of oil system.
NOTE
Tag all lines, hoses, wires, and tubes to aid in installation.
Care must be taken to ensure that fluids are contained during performance of inspection, main-
tenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suit-
able containers before opening any compartment or disassembling any component containing
fluids.
Dispose of all fluids according to local regulations and mandates.