TM 5-3800-205-23-2
THIS WORK PACKAGE COVERS
Bleeding
INITIAL SETUP
Equipment Condition
Maintenance Level
Unit
Machine parked on hard, level surface (TM 5-3800-
205-10-1)
Tools and Special Tools
Scraper bowl lowered to ground (TM 5-3800-205-
10-1)
Shop equipment, common no. 1 (Item 24, WP
Parking brake applied (TM 5-3800-205-10-1)
Materials/Parts
Wheels chocked (TM 5-3800-205-10-1)
Battery disconnect switch in OFF position (TM 5-
3800-205-10-1)
Personnel Required
Rear compartment access cover opened (TM 5-
3800-205-10-1).
Two
CAUTION
Ensure that brake fluid reservoir, air/hydraulic brake cylinder, and caliper bleed screws are free
of external contamination such as dirt, grease and oil. Failure to follow this caution may result
Ensure that brake fluid reser-
1
voir is full prior to connect-
ing power bleed unit. Failure
to follow this caution may
cause damage to brake sys-
tem.
1.
Connect power bleed unit to brake fluid reservoir (1).
2.
Using power bleed unit, allow system air pressure to
reach 125 psi (862 kPa).
390-012
390-120